Brief: Discover the IEC 60332 Single Insulated Cable Vertical Flammability Chamber, designed to test the fire resistance of your cables. This chamber ensures compliance with international standards, offering precise and reliable results for your safety needs.
Related Product Features:
Compliant with IEC 60332-1-1, 1-2, and 1-3 standards for vertical flame propagation tests.
Features an integral air-intake automatic ignition system for quick and efficient combustion.
Equipped with a dual flow meter for precise control of gas flow (650±30mL/min propane, 10±0.5L/min air).
Includes a 7-inch color touch screen for easy operation and monitoring (optional PLC control).
Test chamber dimensions: WDH=300×450×1200±25mm, suitable for various cable sizes.
Flame height adjustable: inner flame 55±5mm, outer flame 180±10mm for accurate testing.
Temperature measuring copper block ensures precise flame verification (heating time 45±5s to 700°C).
Optional fume hood available for enhanced safety during testing.
FAQ's:
What standards does the IEC 60332 Single Insulated Cable Vertical Flammability Chamber comply with?
The chamber complies with IEC 60332-1-1, 1-2, and 1-3 standards for vertical flame propagation tests on single insulated wires or cables.
What type of gas is required for the flammability test?
The test requires >95% propane gas or coal gas, with a flow rate of 650±30mL/min propane and 10±0.5L/min air, controlled by dual flow meters.
What are the dimensions of the test chamber?
The test chamber dimensions are WDH=300×450×1200±25mm, designed to accommodate single insulated wires or cables up to 600±25mm in length.